I am confused. Why are you working on the output mux when the problem seems to be with the front panel input circuitry? The DAC calibration procedure does not involve IC18 at all. Only the comparator that drives pin 1 of the CPU, and the two pots, and the analog mux that selects their voltage and feeds it to the comparator. I would focus on those components. Bob ________________________________ From: "josh.nursing@gmail.com" <josh.nursing@gmail.com> To: PolySix@yahoogroups.com Sent: Friday, January 10, 2014 1:09 PM Subject: Re: [PolySix] RE: Lots of pots not working, MG, VCF, EG. What could be the reason that IC18-P12 (Res) picks up the signals from all other Pots? There do not seem to be any continuity or shorts problems around IC18, and the traces for P2.0 - 2.3 & INH2 are fine. The CPU should be okay too and I swapped new 4501 at IC18 & 19 at one point, and a second time reverted these and used the new 4501 on the two left-most panels. Doesn't this narrow it down to either the DAC or the comparator at IC6? Yash
Message
Re: [PolySix] RE: Lots of pots not working, MG, VCF, EG.
2014-01-10 by Bob Grieb
Attachments
- No local attachments were found for this message.