Discussion about the Korg PolySix synthesizer group photo

Yahoo Groups archive

Discussion about the Korg PolySix synthesizer

Index last updated: 2026-04-03 22:22 UTC

Message

RE: [PolySix] LFO problems again

2013-02-17 by Malte Rogacki

If I may add to this: I recently had a similar problem, but the culprit
wasn't the connector on KLM367; the problem was the connector on KLM369.
Cleaning that one got rid of the bleedthrough. The LFO signal from the
KLM367 to the control panel and the wheels and the return signal from the
wheel are on adjacent pins in this connector.


At 8:31 Uhr -0500 16.02.2013, backshall1 wrote:
> I've had a couple where I had to remove the connector header from the board,
> clean the bottom of the header and the board, then solder it back on. That
> was a real pain but it fixed the problem when doing the jumper didn't help.
> Apparently there was some leakage from pin 1 to pin 2 of CN06 underneath the
> header.