Hi Daniel, You are looking for 1 volt p-p, but VR2 does nothing and you have 3.8v p-p? Does decreasing the MG level control do anything to the output? You should have this set to 10 when making adjustments here. What do you have at IC14 pin 7 with MG level at 10? Cheers, Andy On 26/08/2010 19:17, "Daniel A" <apophis93@yahoo.com> wrote: > > > > > > Any thoughts on how I should track down this voltage issue? > > Thanks! > -Daniel > > --- In PolySix@yahoogroups.com <mailto:PolySix%40yahoogroups.com> , "Daniel A" > <apophis93@...> wrote: >> > >> > >> > >> > Andy, >> > >> > If I am getting the 50Hz cycle but the peak to peak voltage is at 3.8v and >> VR2 is not changing the value.What componants are to be examined if the >> voltage is not in line? The manual refers to LM3600 (LM3700) R98 and R52. >> > >> > - Daniel >> > > > > > > [Non-text portions of this message have been removed]
Message
Re: [PolySix] Re: (new) KLM-367 Calibration
2010-08-26 by Andrew Jury
Attachments