Andy, Well it seems it was a continuity issue. All solder points from the bottom of the board looked clean. So I went over the top of the board and looked for any points that had very little solder and just reapplied. Now I am past initial calibration and onto using my oscilloscope. As I have not done this calibration with my scope I do have one newbie question. When the service manual states to observe CN03-5 is it asking me to pull the Molex connector (CN03) and probe pin 5? or should I be using the nearby test point? Thanks! Daniel
Message
Re: (new) KLM-367 Calibration
2010-08-22 by Daniel A