It's possible you turned the Reset trimmer too far to the left -- try turning it back, and see if that helps. ~GMM analogsynthservice.com petrolio77 wrote: > > > Hallo to all p6 lovers! > I' m Pietro from Italy and I have a question for you .. > After ten years of good playing my p6 start to don't save the sound > anymore....I mean that the old sound were still there but nothing on > new one saved so I thought ...bad battery....no. > So I decide to do the adjustement procedure explained in the service > manual...the voltages were ok but when I disconnected the 56k resistor > the normal (program a1) does not comed back (trying to switch from > test to normal too).(It is possible I shorted the 2p connector > accidentaly) > Panic > switch off and on again but nothing. > all the light are on always. > > so I check the board (klm367) with the tester and seems ok ...no acid > leaking around. > > Maybe the uP is dead ! but I don't know how to test it. > > I need HELP. > > thanks to you all. > Pietro > > [Non-text portions of this message have been removed]
Message
Re: [PolySix] P6 Herthattak
2010-03-06 by klosmon
Attachments