Re: [PolySix] one voice does not sound when VCA switch is set to EG

2010-02-07 by Andrew Jury

Hi,

When you switch to EG mode does this non-sounding voice still light the LED?
As a generic answer, you might want to perform some comparative measurements
around bi-lateral switch IC35 and around emitter follower stage Q5 with the
other working voices. My guess is that there is a problem somewhere in this
vicinity.

Good luck and don¹t forget to tell us how you get on.

Cheers,
Andy


On 06/02/2010 22:49, "Alexis V. Rogers" <alexis.v.rogers@gmail.com> wrote:

>  
>  
>  
>    
> 
> One of the voices on a PolySix I'm looking at does not sound when the VCA
> switch is set to EG. It does sound when the switch is set to waveform. I tried
> swapping IC34 SSM2056 on that voice with another working voice but the problem
> did not follow. Does anyone have any suggestions on where else to look?
> Thanks, Alex
> 
>  
>    
> 
> 



[Non-text portions of this message have been removed]