I found the issue. I reseated the IC that was replaced during the battery procedure. (put it in a socket instead of directly on the board) --- In PolySix@yahoogroups.com, "sdlarch1" <sdlarch@...> wrote: > > > According to the calibration manual, the waveform at CN03-5 should look > like this: > > [Click for a larger image. Opens in a new window] > <http://01eea9c.netsolhost.com/poly6/cal_snipet_large.jpg> > > Mine looks like this: > > [Click for a larger image. Opens in a new window] > <http://01eea9c.netsolhost.com/poly6/cn03-5_read_large.jpg> > > The controls are set like this: > > [Click for a larger image. Opens in a new window] > <http://01eea9c.netsolhost.com/poly6/vca_adjust_presets_large.jpg> > > Does anyone see something blatantly wrong? Any ideas? I've performed the > battery swap. I went throught the cal procedure after the battery > operation and this waveform looked fine. The only other mod I've done is > that PC1 was replaced with a VTL5C3 and R93 was changed to a 1k2 ohm. > -Sam > > > > [Non-text portions of this message have been removed] >
Message
Re: VCA Calibration looking bleak
2007-10-10 by sdlarch1
Attachments