Does it happen only to one of the 8 oscillators ? if so, replace its SSM2044 chip.... --- In PolySix@yahoogroups.com, "roisto" <roisto@...> wrote: > > I mean that filter of the last two oscillators has somehow turned to > work negative. When cutoff filter is opened, one oscillator plays it > closed (like lowpass effect), and vice versa, when filter is closed, > one oscillator plays filter totally opened. Two modes at the Eg- mode > seems to change this effect between 7th and 8th osc. Thank you for > you reply. > > -t > > > > --- In PolySix@yahoogroups.com, "gil_we" <gil_we@> wrote: > > > > What do you mean by "opposite way" ?? > > > > The replacements seems fine to me. > > > > > > > > > > > > > > --- In PolySix@yahoogroups.com, "roisto" <roisto@> wrote: > > > > > > I just got this synth and it has something wrong with 7th and 8th > > > voices. When i´m adjusting eg intensity, filters for the last two > > > voices are working opposite way :) i opened it and found that all > the > > > vcf:s were SSMT2044 except voice 8 wich was SSM2044 (maybe > someone > > > has changed one or all of them?!) and MC14066B chip at the 8th > voice > > > has been replaced with F 4066BPC (having "indiana" text on it).. > > > anyways battery was brand new inside the trident, and everything > else > > > seems to work 100%. Any ideas how to fix this? > > > > > >
Message
Re: Trident mkI filter problem
2007-10-05 by gil_we
Attachments