I mean that filter of the last two oscillators has somehow turned to work negative. When cutoff filter is opened, one oscillator plays it closed (like lowpass effect), and vice versa, when filter is closed, one oscillator plays filter totally opened. Two modes at the Eg-mode seems to change this effect between 7th and 8th osc. Thank you for you reply. -t --- In PolySix@yahoogroups.com, "gil_we" <gil_we@...> wrote: > > What do you mean by "opposite way" ?? > > The replacements seems fine to me. > > > > > > > --- In PolySix@yahoogroups.com, "roisto" <roisto@> wrote: > > > > I just got this synth and it has something wrong with 7th and 8th > > voices. When i´m adjusting eg intensity, filters for the last two > > voices are working opposite way :) i opened it and found that all the > > vcf:s were SSMT2044 except voice 8 wich was SSM2044 (maybe someone > > has changed one or all of them?!) and MC14066B chip at the 8th voice > > has been replaced with F 4066BPC (having "indiana" text on it).. > > anyways battery was brand new inside the trident, and everything else > > seems to work 100%. Any ideas how to fix this? > > >
Message
Re: Trident mkI filter problem
2007-09-20 by roisto
Attachments