Gus, I ported uIP to the E2124 and it works on that part, but that's in polled mode. I don't have a port of uIP for that board as I don't have the board. If you have any success with it, please let me know--I'd be interested to see what you make of the board as it's way over specified to run uIP, better would be lwIP. -- Paul Curtis, Rowley Associates Ltd http://www.rowley.co.uk CrossWorks for MSP430, ARM, AVR and (soon) MAXQ processors > -----Original Message----- > From: Gus [mailto:gus_is_working@...] > Sent: 07 February 2005 15:39 > To: lpc2000@yahoogroups.com > Subject: [lpc2000] olimex LPC-E2294 with ethernet > > > > Hello, > > I spent all weekend trying to get the ethernet to work on olimex LPC- > E2294 board http://www.olimex.com/dev/lpc-e2294.html with no luck > > Looking at the board schematics, they have the Ethernet chip > "selected" all the time through R57!!! This is WRONG!! I > don't understand why!!! So I removed R57 and installed R56 > instead. Now, when I read the chip, I always get the "chip > ID" no matter what register I select! > > Was anyone able to read the registers from CS8900A? Any > hints? Even with thier test code, I wasn't able to get things > going. The plan is to get uIP going on that board > http://www.sics.se/~adam/uip/ > > Thanks, > > Gus > > > > > > > > Yahoo! Groups Links > > > > > > > > >
Message
RE: [lpc2000] olimex LPC-E2294 with ethernet
2005-02-07 by Paul Curtis
Attachments