--- Robert Adsett
<subscriptions@...> wrote:
---------------------------------
At 08:46 AM 1/9/05 +0000, you wrote:
>I've had the UARTs on the LPC21xx LPC22xx running
fine at 115.2k (e.g.
>receiving large files with 32 bit CRCs). It just that
the divisor
>arrangement means the baud rate @ 12MHz is approx 1%
out (with the PLL
>multiplying the XTAL by 5 to 60MHz / VPBDIV = 1). I
just wondered
>whether the bootloader on the chip gives up if it
can't get an exact
>baud rate...
Remember the ISP program on chip doesn't use the PLL
(at least there is no
indication that it does) so a 1% mismatch at the
(pll'd) 60MHz could be a
5% mismatch at 12MHz native clock. You can see the
problem.
Yes I see the problem. I'll have a chat with Philips.
Jane
Robert
" 'Freedom' has no meaning of itself. There are
always restrictions,
be they legal, genetic, or physical. If you don't
believe me, try to
chew a radio signal. "
Kelvin Throop, III
---------------------------------