Re: [lpc2000] Re: Philips Flash Utility V2.2.0 (max baud rate = 38400???)

2005-01-09 by jane highland

--- Robert Adsett
<subscriptions@...> wrote: 

---------------------------------
At 08:46 AM 1/9/05 +0000, you wrote:
>I've had the UARTs on the LPC21xx LPC22xx running
fine at 115.2k (e.g.
>receiving large files with 32 bit CRCs). It just that
the divisor
>arrangement means the baud rate @ 12MHz is approx 1%
out (with the PLL
>multiplying the XTAL by 5 to 60MHz / VPBDIV = 1). I
just wondered
>whether the bootloader on the chip gives up if it
can't get an exact
>baud rate...

Remember the ISP program on chip doesn't use the PLL
(at least there is no 
indication that it does) so a 1% mismatch at the
(pll'd) 60MHz could be a 
5% mismatch at 12MHz native clock.  You can see the
problem.

Yes I see the problem. I'll have a chat with Philips.

Jane

Robert

" 'Freedom' has no meaning of itself.  There are
always restrictions,
be they legal, genetic, or physical.  If you don't
believe me, try to
chew a radio signal. "

                         Kelvin Throop, III



---------------------------------
Yahoo! Groups Links

   To visit your group on the web, go to:
http://groups.yahoo.com/group/lpc2000/
 
   To unsubscribe from this group, send an email to:
lpc2000-unsubscribe@yahoogroups.com
 
   Your use of Yahoo! Groups is subject to the Yahoo!
Terms of Service.
 


	
	
		
___________________________________________________________ 
ALL-NEW Yahoo! Messenger - all new features - even more fun! http://uk.messenger.yahoo.com

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.