Hi All I modified Martin's lpc21isp ISP tool a few days back and emailed him, but didn't get a response so I've posted the modified version on the group. Martin: I hope that's OK with you... Anyway, the reason I modified the ISP loader was mainly because it would not synchronise effectively with my LPC2106 board. What I found was that the ISP tool, like the Philips Windows-based tool, would only send out one '?' to attempt the synchronisation but sometimes needed more. I found that sometimes up to 75 '?' were required to start up properly. The code is also set up to work under Windows (though I've only used it under Linux) so it might be of help to people who are having problems with the Philips Windows tool. -- CHarles