Korg Poly800/EX800 Users group photo

Yahoo Groups archive

Korg Poly800/EX800 Users

Archive for korgpolyex.

Index last updated: 2026-03-30 01:10 UTC

Message

Re: [korgpolyex] Re: Check and adjustment procedure

2017-05-27 by Michael Hawkins

No, you can't do that with a multimeter because it will read the RMS value instead of peak to peak.

Use your oscilloscope, set the sweep to somewhere from 50uS to 20mS. Then make sure the white noise level is 0.3V from lowest to highest (peak to peak).

/Mike


From: "purpurinisukutis@... [korgpolyex]" <korgpolyex@yahoogroups.com>
To: korgpolyex@yahoogroups.com
Sent: Saturday, May 27, 2017 4:55 AM
Subject: Re: [korgpolyex] Re: Check and adjustment procedure

 
Hello again, maybe last question about this topic... :) Noise level check and adjustment: connect oscilloscope to KLM-596 CNA 3 pin and confirm noise level of 0.3 V p-p (+-20%).  How to do that with oscilloscope? I am using old russian C1-94. Maybe i can do the same with voltmeter?


Attachments