Re: Unable to send a SYSEX to EX800

2013-03-05 by benoitdmx

I do not think so (you speak about Parm 86, right ?)
Anyway, I just made a test with 86 set to 1 : same result. I can write whatever I want in the program parameters, it is never replaced by the sysex data.

To make sure that the Write Enable switch was not broken, I tried to store a parameter with the switch set to Disable : EX800 does not accept when I try to push the Write button (so I assume the Write Enable switch is working)

Benoit

--- In korgpolyex@yahoogroups.com, Michael Hawkins <korgpolyex800@...> wrote:
>
> I think you also need to set program enable in EX800 parameter - right?
> 
> 
> mike
> 
> 
> 
> ________________________________
>  From: benoitdmx <benoit.bouchez@...>
> To: korgpolyex@yahoogroups.com 
> Sent: Tuesday, March 5, 2013 10:37 AM
> Subject: [korgpolyex] Re: Unable to send a SYSEX to EX800
>  
> 
> Â  
> Hi Mike,
> 
> that's the first thing I have checked (it's on Enable). Moreover, I think that if this switch would be in Disable position, loading a tape would be impossible (not sure anyway)
> 
> Benoit
> 
> --- In korgpolyex@yahoogroups.com, Michael Hawkins  wrote:
> >
> > You have to set the Program Enable switch on the back to Enable. If it's set to disable then the patch data in the dump will be ignored.
> > 
> > The same applies to the sequencer data in the dump. If the sequencer enable switch is set to disable then the EX800 will ignore the sequencer data.
> > 
> > It was done that way so that you could load up patch data but not sequencer data or load sequencer data but not patch data or load them both.
> > 
> > mike
> > 
> > 
> > 
> > 
> > ________________________________
> >  From: benoitdmx 
> > To: korgpolyex@yahoogroups.com 
> > Sent: Tuesday, March 5, 2013 9:10 AM
> > Subject: [korgpolyex] Unable to send a SYSEX to EX800
> > 
> > 
> >   
> > Hello all,
> > 
> > I am facing a strange problem with my EX800. I have the SYX file for factory (and also some SYX files I made after sending a dump request to the EX800 - note that it is a non-modded one, still original hardware)
> > 
> > When I send the SYX file to the EX800, the synth clearly receives it (the display goes blank while it receives the MIDI data). I get no message back from the EX800 then (it seems correct because if I change the checksum, the EX800 reports a dump error after receiving the file)
> > 
> > Here is what I see : if I edit a parameter (let's say param 18, set to 2 originally) and I reload the SYX file, the EX800 is clearly ignoring the SYSEX. The data I see in the changed parameters are still the same than BEFORE uploading the SYX file. It looks like the synth is ignoring simply the valid SYSEX data. If I reload the data from cassette interface, it works (the parameters I have changed are restored to original value)
> > 
> > Is there something special to send to the synth *before* sending the data dump (to tell him "I will now send you the RAM dump") ?
> > 
> > I am working on this problem since 2 weeks, and I am simply getting crazy. I can't understand why the EX800 does not take into account the SYX data he has just sent before
> > 
> > Is there a change between a dump going to the synth and a dump coming from the synth ?
> > 
> > Thank you by advance for your help
> > 
> > Benoit
> >
>