Should work fine. Install a good socket if you want. Then you can use a TL072 when you get one. --- In korgpolyex@yahoogroups.com, "selloutdesigns" <aah_public@...> wrote: > > Anyone know offhand if a tl082 can safely replace a tl072? They do appear compatible. > > Thanks, > > <<aaRoN>> > > --- In korgpolyex@yahoogroups.com, Gordon JC Pearce MM3YEQ <gordon@> wrote: > > > > On Wed, 2009-03-04 at 13:34 +0000, narfman96 wrote: > > > Definitely timing issues with IC36b the interrupt oscillator. Try > > > disconnecting the output at R107 and see if it runs at the correct > > > frequency. If it does the CPU is loading it down somehow. If not then > > > suspect the timing caps C76 or C79. The resistors R102-R104 need to be > > > verified and then the Tl072 op amp itself. This circuit needs to run > > > in the mhz or no go for the LED display and envelope generators. > > > > Bah. Just change the TL072 on spec. Horrible things. > > > > Gordon > > >
Message
Re: Dead 800
2009-03-04 by narfman96