Thanks !! You help me a lot. ok I guess you meant R109 : 42,1 Kohm (not ohms) as the Resistor is 100K. I can now turn it up safely I guess ;) I will also document these values for other, when coming across the same issue. --- In emulatorII-list@yahoogroups.com, zom <zomnius@...> wrote: > > Hello, > > I am measuring > > R110 : 1,39ohm (measured at 20k ohm range) > > R109 : 42,1ohm (measured at 200k ohm range) > > cheers Zom > > > 2011/8/8 zom <zomnius@...> > > > I will do this now for U. > > > > > > > > 2011/8/8 Gil <gilwe@...> > > > >> ** > >> > >> > >> Hello friends. > >> > >> As I posted before, I have a little trouble with my E-II. I recapped the > >> power supply, and mistakenly tweaked the two trimpots marked R109 and R110, > >> both appearing on the right side of the power supply circuit. It appears > >> there is not calibration procedure for them available, so the only way I can > >> set them back to their "factory" positions is to get the values from another > >> E-II... Will any of you be kind enough to measure these two trimpots in his > >> E-II and let me know the values across their legs (as set in the factory) ? > >> this way I will be able to set them back to where they should be, and make > >> use of my E-II again.... > >> > >> Thanks very much for the help !! > >> > >> > >> > > > > >
Message
Re: Will someone please measure two trimpots in E-II power supply ?
2011-08-09 by Gil
Attachments