> From: rob.ocelot@... > > At the moment I'm testing the Frankenstein's membrane panel > and the panel boards in the Good Polaris. So far almost every > function works except for the sweep rate slider (probably > dead) and the far right column of membrane buttons and LED's > do not function, along with the Detune button. > > Anybody know which panel matrix trace corresponds to these buttons? The service manual is here: http://www.rhodeschroma.com/?id=polarisservicemanual The line common to those switches is the SW7 line, which is on connector J9B pin 9 on the right board. First, make sure the tail is properly aligned with the connector pins. Then, you might also look inside the connector with a magnifier to see if there's any crud from the old tails clogging it up. It's hard to imagine a failure in one of the electronic parts causing the problem, because the only parts that are involved are R16, a 1/4W resistor, and one section of Z3, an LS-TTL chip. -- Ciao, Paul D. DeRocco Paul mailto:pderocco@...
Message
RE: [chromapolaris] Column of membrane buttons not working
2015-02-03 by Paul D. DeRocco