> From: lukas.switlicki@... > > Maybe I should ask a techy, but this group seems informed so why not. > > The bottom row of my right membrane panel ( the last row of > preset buttons) doesn't respond anymore, and currently I'm > trying to permanently repair and strengthen the ribbon cables. > > I want to figure out which cable is the faulty one though, > are the two ribbons on the right side (at the bottom of the > right panel) the one's responsible for controlling the preset > buttons, or is it the two ribbons coming in and entering from > the left side? If there are any technicians or DIYers that > know the answer I'd really appreciate it. Both tails are involved; one has the row connections and the other has the column connections. The panels were made out of some material other than real Mylar, which turned out to harden and crack over the years. The solution is to replace the panels. I sell replacement panels, which many people on this list have installed. Contact me off list, and give me your address for a quote. You can see the replacement process here: http://www.rhodeschroma.com/?id=polarismembranepanelreplacement -- Ciao, Paul D. DeRocco Paul mailto:pderocco@...