Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Re: negative values with bc-manager

2015-05-26 by rpcfender@...

It is mighty confusing.

F0 10 06 (x) F7
turns into BCL (Behringer Conrol Language)
. tx $F0 $10 $06 val $F7

Most if the stuff I was talking about is for the range
.minmax $42 $BF

So for encoder 1 the BCL is

$encoder 1
.mode 1dot
.minmax $42 $BF
.default $42
.resolution 96 96 96 96
.tx.$F0 $10 $06 val $F7

I program in BCL, as above, for the BC gear and not Mark's excellent graphic editor, but I think you just use the 'Custom Output' for the sysex message and set the mode, range (minmax) etc as normal.

Royce

Attachments

Move to quarantaine