2003-02-06 by DarkStr717@aol.com

In a message dated 2/2/03 3:49:50 PM, jan-hinnerk.helms@... writes:

<< First, comparing the unquantized and quantized signal as it controlled an
NTO through its 1V/Oct input revealed, that the QTKB's response times are
quite audible - as a short but noticeable portamento, even when using the
QTKB with the TKB as the input source.

Second I was a little bit disappointed with the scaling of the Decay and
Release times of the ADSR. As much as I appreciate a fine resolution of the
shorter Decay and Release times, I have to say that it surprised me that the
more noticeable changes in these times started occuring from 1 o'clock
upwards of the control setting, regardless of the curve switch setting. >>