2002-09-09 by spr@spridley.freeserve.co.uk

> of them had a pulse sequencer which basically went from pulse output
> 1 to pulse out 8 or 10 by a clock source at its input. if you patch
> the outputs sequentially to the programmer stage address inputs, they
> would fire in order. i am not sure if this is correct, but it seems
> to be the way it was intended. i wonder how the pulse input on the
> pulse sequencer reacted to smooth voltages of any type? hope this
> helps.

The problem is, this set up is shown in one of the old serge
manuals, but it doesn't work with more than one standard
programmers. Using the standard 4 stage programmers, the first
four steps come out of programmer #1 and the next four come out
of programmer #2. Also, because programmer #2 does not reset
programmer #1, when step 5 (step 1 of programmer #2) is selected,
step 4 (step 4 of programmer #1) stays on.

It's not difficult to bodge it to work (join the reset buses
and combine the outputs in some way), but it would be very
interesting to see the proper Serge way of doing it...