-----Original Message----- From: kennyb@... [mailto:kennyb@...] Sent: Tuesday, August 29, 2000 11:12 PM To: analogue@... Subject: [AH] Jupiter-6 fix update Hi AH, I posted a few tips about JP-6 repair and then asked for help as mine went out a few days later... thought I would give an update on where I am at. The problem: VCO-2 on both voice boards always drifts out of tune by something like a semitone. Pressing lock VCO1->VCO2 makes VCO2 lock on perfectly. It does not matter whether mono/poly/split is on. Its always the same. What I did: I did the full calibration procedure and looked around visually to see if any of the cable harnesses were loose. The calibration did not fix it, no cables were loose. My threory: I suspected that it is the CPU board that has the problem. The VCO2 offset is controlled from there. I could not find the problem and do not have the full schematics so I had to bring it in. Now: Its at Roland being fixed by Tony (nice guy). He has found that corrosion from the original battery (now replaced) has eaten through the traces on the underside of the CPU board. There are tons of things wrong with it. Its a big job. Anyhow, I hope this helps someone. Cheers, Kenny B.
Message
FW: [AH] Jupiter-6 fix update
2000-08-30 by Verschut, Ricardo
Attachments
- No local attachments were found for this message.