Yes, I have the hole drilled as specified, .026 D (#71 drill I think), 4mm ED, 2.5" from sensor CL. as pictured. Upon initialization, I checked voltages as indicated in the second chart below. I measured the resistor on the board you provided, which is marked 3002 and measures 30.1k. I thought that was to be 4.99k. Could that be the problem?
Thanks,
Roger
E260dn DLP Hookup
Device
Function
Conn
Color
ATtiny13 MCU
Function
Operator Panel
3.3V
J5-5
BL
2
Pad no.’s = Pin no.’s
PB3
Cover Open
Switch Wires
5V
J7-1
YE
8
VCC
5V
J7-2
RD
GND
J7-3
BK
4
GND
Thermistor Substitute
5V
J12-1
BK
(J12-1>2.7k>J12-2)
(RD-VI-RD)
Fuser Temp
GND
J12-2
BK
New Paper In Sensor
(was narrow sensor)
0-5V
J14-1
RD
(Splice J14-1 wire to Sensor)
5V
J14-2
WT
7
Pad no.’s = Pin no.’s
SCK
GND
J14-3
BK
4
GND
Sensor
RD
(Splice Sensor wire to J14-1)
Sensor
BL
5
(4.99k to PAD 8 VCC?)
(Measures 30.1k)
MOSI
GND
Sensor
BK
4
GND
Manual Feed
Paper Sensor
5V (1.1V)
J23-1
BL
Open
Pad no.’s = Pin no.’s
5V
J23-2
WT
6
MISO
GND
J23-3
BK
4
GND
Duplex Sensor