Just took a look at information from Weller. They recommend that you only use a synthetetic wet sponge to clean the tip. They do not recommend rags or cloths. They recommend frequently cleaning the tip and retinning right after cleaning. They also recommend using distilled water instead of tap water to avoid the mineral content found in most tap water. I have been know to use other things to clean the tip especially in the field, but I have to say that the wet sponge is the best I have seen. A number of the guys at work use the brass pads that have been out for a number of years now or atleast that I have seen them but I have always wondered about tip wear with these. Personal have not used them due to that. The wet sponge has been working for me for 25+ yrs of professional soldering. In Jr. High and High School I used the sling method or whatever was handy to wipe it on. The sponge is cleaner and neater. Yes in the field it is inconvenient but is what I find to give the best results. Ben
Message
Re: New Soldering station - WOW
2003-08-26 by Ben H. Lanmon
Attachments