--- In Homebrew_PCBs@yahoogroups.com, "Roland F. Harriston" <rolohar@...> wrote: > > > > Repeat.............. > > Don't use metals around Ferric Chloride.........period. > Please let me clarify the HCL and H202 HCL is standard Muriatic Acid (aprox 33%)availible at walmart $4.00/gal H202 is 3% about a dollar per quart also at walmart the kind used to treat cuts I might add neither are temperature sensitive. I store both in a outside garage with extremes of temperature both summer and winter. Just make sure you dont store the HCL near anything metal because some fumes will leak out and corrode it. Water dilutes the acid and I alway have a full 5 gallon bucket of water near me when I etch. After the etching is completed I carefully remove the pcb and rinse it in the bucket. Then I just dump the etchant into the five gallon bucket. This makes the disposal easier as the solution is then only mildly acidic. Be carefull dont get your eyes anywhere close to the etchant. Dennis Waggoner
Message
Re: Etching tank, build or buy?
2007-11-25 by Dennis Waggoner
Attachments