Each of the 3.5mm sockets has a GND terminal and as soon as a connection is made to external equipment a GND loop may occur. If the rails are connected to GND/Earth or not is not that important (though they are finally also connected to GND/Earth via the front panels as soon as modules have been installed). Best wishes Dieter Doepfer > Hello Dieter > > On 13.06.16 09:34 , yahoo@doepfer.de [Doepfer_a100] wrote: > > The hum is probably caused by a ground loop. Due to safety reasons all metal parts of the A-100 cases are connected GND > AND to earth > > shield of the mains connector. > > Scott wrote > "No the rails are not connected to ground. This is the way Doepfer built > the box and I was not advised to change it." > > These are LC9 cases. Are those cable in a different way? > > > Florian
Message
AW: AW: [Doepfer_a100] Re: Loud ground loop hum
2016-06-13 by yahoo@doepfer.de
Attachments
- No local attachments were found for this message.