Re: A-156 Dual Quantizer Transpose issue

2015-03-23 by karelvanbezooijen@yahoo.com

I think I'm going insane! I've soldered the 330K resistor this time.

Again the upper Quantizer is used.

CV In = 1.000 volt, CV Out 0.923 volt. But sometimes (very sometimes, rare is better) it reads 1.006 volt again.
At that moment only when I unplug the CV In it reads 0.85 volt.

Next.

CV In = 0 volt
Transpose CV IN = 1.000 volt, CV Out = 1.006 volt.
Transpose CV IN = 2.002 volt, CV Out = 2.002 volt.
I can reproduce this over and over.

So, this time the transpose function is OK, but the CV In isn't.

During the tests I've adjusted P3 so probably it isn't in the original setting anymore.

Best regards,
Karel.