I prefer the normalized version of the connection myself because this allows to easily dis-connect the VCO from the bus when wanted. I often do this when using the Buss Access modules on a cabinet with more than one "receiver" from the bus. Often a situation will come up where you want to NOT have the VCO transposed by another signal on the bus. It also adds to some confusion when you have a VCO changing pitch (from the bus) when you are doing it from another module and forget about the normalization. I would probably not use the built in connection and make a separate one through the normalized jacks myself. I understand doing this on modules that only have one front panel CV in like the A-111-5 though, Doing this allows it to have 2 CV ins when normally it doesn't. Not much room to add a jack there. -James > On Oct 29, 2014, at 8:58 AM, Neil Kagan blinkenlicht@yahoo.com [Doepfer_a100] <Doepfer_a100@yahoogroups.com> wrote: > > Thanks for the incredibly quick reply Dieter - I’m new to the Eurorack scene and have built a 100% Deeper system which sounds incredible. Just learning as I go! > > Regards, > > Neil > > >> On 29 Oct 2014, at 15:55, yahoo@doepfer.de [Doepfer_a100] <Doepfer_a100@yahoogroups.com> wrote: >> >>> Sorry to post twice in one day! >>> >>> Does anyone know if there is a reason my A-111-1 doesn’t have a ‘normalised’ CV1 input? My A-110-1 breaks connection to >>> the CV bus as soon as a cable is inserted which is how I understood it to work in general. However, the A-111-1 doesn’t >>> which means I’m getting more control signals than I want! >>> >>> Thanks, >>> >>> Neill >> >> Indeed there is a inconsistency in the CV handling of the A-110 and the A-111-1. But as far as I know it's described correctly in >> the user manuals of the modules. The A-110 uses a normalled socket with switching contact to interrupt the bus CV as soon as a plug >> is inserted into the CV socket at the front panel. For the A-111-1 (and all other later modules that have access to the bus CV, e.g. >> A-111-5, A-111-2) the CV's of the bus and the front panel socket are added. We found that this is more flexible than the normalling >> version. And there is another reason: over the years (the A-100 is nearly 20 years on the market) the switching contacts may wear >> out because of inevitable material fatigue or corrosion or unwanted dust between the metal parts of the socket. That why we try not >> to use normalled sockets if it's avoidable. >> >> Best wishes >> Dieter Doepfer >> >> >> >> >> >> >> >> ------------------------------------ >> >> ------------------------------------ >> >> >> ------------------------------------ >> >> Yahoo Groups Links >> >> >> > > > > ------------------------------------ > > ------------------------------------ > > > ------------------------------------ > > Yahoo Groups Links > > >
Message
Re: [Doepfer_a100] Oscillator CV ins
2014-10-30 by james.husted@mac.com
Attachments
- No local attachments were found for this message.