2013-11-14 by Florian Anwander

Hello Steve,

as Dieter wrote you may use the Hard-Sync. But it won't solve your click 
problem, because the hard sync resets to the minimum of the waveform. To 
avoid the click at very fast attack rates you would have to reset to the 
zero crossing (=the middle) of the waveform.

The tempest can do it because the waveforms are generated digitally.

Florian

On 14.11.13 01:06 , modular_steve@yahoo.com wrote:
>
>
> Hello again! Is there a module that resets waves every time they're
> triggered? I think clicking might be reduced if a wave was always
> triggered at the beginning of its cycle. The DSI Tempest does this
> pretty successfully. Just food for thought :). Regards, Steve

Attachments