thanks Dieter! 2013/5/3 <yahoo@doepfer.de> > ** > > > Not the clock signal but the reset signal triggers the reset, i.e. a > positive voltage (not the rising slope !) at the reset input resets all > A-160 outputs to zero and A-161 to step 1. The reset is static, i.e. as > long > as the reset signal is high all A-160 outputs remain low and A-161 stays at > step 1 (even if clock pulses are present). Clock and reset are independent > from each other for A-160/A-161 combo (in contrast to the A-154 where a > reset signal triggers kind of a "wait state" and the actual reset is > carried > out at the next clock pulse that follows the reset). > > Best wishes > Dieter Doepfer > > > -----Ursprungliche Nachricht----- > > Von: Doepfer_a100@yahoogroups.com > > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von Peter Sedin > > Gesendet: Freitag, 3. Mai 2013 08:09 > > An: doepfer_a100 > > Betreff: [Doepfer_a100] a-160/161 question > > > > > > > At muff wiggler I read that the clock pulses does not reset the divisions > after reset. > > like in the picture.. why not??? > > > > > > Mvh > > > > Peter H.K Sedin > > > -- Mvh Peter H.K Sedin [Non-text portions of this message have been removed]
Message
Re: [Doepfer_a100] a-160/161 question
2013-05-03 by Peter Sedin
Attachments