> Hi again! > > So I'm removing the gate and CV bus access jumpers from my > A-190-3, so I can plug its front outputs into the A-185's front > inputs instead... As the A-190-3 doesn't appear to have any > instructions yet, I'm using the A-190-2 instructions as a guide. > I found the "gate bus" jumper (JP2) easily enough, and I *think* > I've found the "CV bus" one too (JP3), but just wanted to make > sure: is it just the bottom jumper? There's three pairs of > jumper pins right next to each other (JP11A and JP11B just above > JP3), then a gap, then a fourth pair (JP10B) for what appears to > be making the gate 12V. So was I right to take out the jumpers > on JP2 and JP3, and leave the jumper in JP11A well alone? > > Thanks! > Zoƫ. I have added page 13 of the preliminary A-190-3 user's manual to the info page of the A-190-3. The document describes the functions of the jumpers. The rest of the user's manual will come soon (but it's 98% identical to the A-190-2). You are right: removing JP2 and JP2 disconnects Gate (JP2) and CV (JP3) from the A-100 bus. Best wishes Dieter Doepfer