Hi Raul, The Doepfer A-100 manual has a chart telling you the amount of mA of each module. Just add the mA amounts hooked to one power supply. Regardless if you run 1 our 4 busses with one power unit. It's the amount of mA each of the attached consumes. Best wishes Jakob Am 29.01.2012 13:26 schrieb "Raul" <raulpena1974@yahoo.com>: > ** > > > Hello group. I'm a bit baffled or naive by the distribution of power in > the two different cases. I'm thinking of upgrading and just wondered if I > need to be more selective and calculating when adding modules? > Up until now i have had 2 G6 cases, and within them I have had various > arrangement of my 90% Doepfer modules. > I know the upper limit of my power supply PSU2 is 1200ma rating. > Perhaps I am overthinking this but how does the larger case with the third > busboard still support more modules? > I feel if I understand this a little better I may lean in one direction > versus another. > Any tips ,rules of thumb, or advice would be useful to me. Thank you. > > Raul Pena > > > [Non-text portions of this message have been removed]