> The exact measuring procedure is a bit more complex for filters that do not > have available self-oscillation. You need a measurement equipment that gives > you the frequency response of the filter and how it changes with the control > voltage (combination of a frequency modulated sine wave over the audio range > as audio signal and an envelope follower at the filter output which gives > you the filter response curve). Yes, I have been doing this manually, because of that lack of self-oscillation! > After that the absolute frequency > of the filter is adjusted to the desired value (i.e. the frequency if all CV > inputs are zero Volt and the manual control is fully CCW). It is what these values are for the factory setup-up of the A-127 that I was really wondering about - e.g. is the cut-off range set to 8 -> 4096Hz, or 16 -> 8192, or 32 -> 16384 or ... what? Thanks again, Tim
Message
Re: A-127 Triple VCRF calibration procedure
2011-04-20 by Tim