Re: A-156 Quantizer problem?

2010-12-06 by Richard Horsman

I just fixed it. Seems that the socket wasn't creating the circuit like it should when no jack is inserted. I pressed the contacts together with the tip of my screwdriver and now it works. It thought there was a jack and there wasn't! Panic over.

Nothing to see hear... move along :-)





Hi

I've just noticed that the top quantizer in my A-156 only quantizes if fed a trigger to its 'Trig In' socket. If nothing is plugged in to this socket then the 'CV OUt' doesn't change at all.

The manual says that if nothing is plugged in it should quantize all the time (which is what my lower quantizer does).

I've never used this top quantizer before as I like the advanced options of the lower one. Is this something that anyone else has seen? Is it fixable?

Thanks

Richard Horsman

[Non-text portions of this message have been removed]