AW: [Doepfer_a100] A-160 Clock Divider modification for Down-counting possible?

2010-11-23 by yahoo@doepfer.de

> Is it possible to modify the A-160 clock divider so that it
> starts with firing all the gates and goes from there? That it
> counts from the top instead of from the bottom. Now I have to
> wait say 32 clocks for it to fire the /32 gate for the first
> time. It would be easier to run multiple clocked devices in sync
> if they all started on the downbeat.
>
> Martin

The A-160 uses a standard CMOS counter (CD4024) that cannot be modified.
Maybe adding inverters do the job you are asking for . In this case all
(inverted) outputs will turn high on each reset.

Best wishes
Dieter Doepfer