> My A-142 bothers me because the only range of short envelopes are > all in the first few degrees from all the way down. As soon as I > get up a bit, the envelopes are a few minutes long and can't even > imagine the lenghths at 6 o'clock. I don't see any jumpers to > change the range levels but wonder if this is how it's made or if > there's something wrong with mine. > > Dan I took a look an A-142 from our stock: The max. envelope time (i.e. Decay control fully CW) should be approx. 10 seconds. The envelope time should change to a minimum of ~ 2 ms in a exponential control scale. Probably the module is misadjusted. Adjust the only trimming potentiometer on the pcb (top right edge) so that the envelope time is ~ 10...20 seconds if the Decay control is fully CW. In addition I took a look at our records. There was a minor change early in 2006. The value of the resistor R6 was set to 120k (instead of 100k). If R6 is 100k there is a small dead range near the CCW position of the Decay control. The control affects the envelope time not until ~ position 2 or 3 is reached. R6 is the resistor below the CV control (left to the word "A-100" on the pc board). If you own an A-142 manufactured before 2006 this dead range will occur. Best wishes Dieter Doepfer