> I programmed a patch with my beautifully tuned VCOs, tonight. > When I decided to use the A155 through a 156 to drive it, I > noticed a significant voltage drop and I had to apply a voltage > from the 176 to bring it back in tune with my other synth. Why > should this be? > > I have also noticed that running the CV from the quantizer > through either the dual or the VC Slew also caused a voltage > droop, regardless of how low the slew setting is. > > Can anyone explain why this might be happening. I'd recommend to use one of the buffer modules A-185-1 or A-1185-2 if several VCOs are controlled by the same CV source. These modules do not load the source and include a buffer that is strong enough to drive several VCOs without voltage drop. Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] Voltage droop when using a quantizer
2009-07-10 by yahoo@doepfer.de