Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: [Doepfer_a100] Re: Ack. Worst day of my life...

2009-02-02 by Sean Williams

Bakis

If they are the first version G6 cases with the all-in-one switch and 
IEC inlet then it's only a matter of time before those big caps fail. 
Be warned! It's quite dramatic, but I don't think any real damage to 
my modules occurred. To be fair, Dieter realized the problem ages ago 
and changed the design, so you may have the old style PSU (650mA) 
with the revised IEC inlet (without capacitor). If not, I hope you 
have a well ventilated studio!

This happened to both my G6 racks in the same month last year - after 
10 years of use. I wish I'd recorded the sound of the capacitor 
fizzing and sputtering but I was too busy pulling the mains out  and 
running out into the street with my Doepfer in my arms so as not to 
set off the fire alarm!

sean

>  > My A-100 is the standard G6 case ordered from Thomann in Autumn last
>>  year. I presume that means a 230V 400ma T (slow blow) fuse: the GL55K?
>
>Yes I should think so. Take a peek at the PSU itself: about half way
>down this page
>
><http://www.doepfer.de/a100z_e.htm>http://www.doepfer.de/a100z_e.htm
>
>you'll see the two types - the older A100NT12 has the 'strikethrough'
>text; the newer A100PSU2 requires the higher-rated fuse, and is easily
>recognised with the big round ('toroidal') transformer on it!
>
>Tim
>
>


[Non-text portions of this message have been removed]

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.