> Hi folks using the A-152 with a cv input immediately gives rise to the > need for a trigger on address selection. I'm thinking a socket for > this could fit at the bottom of the dig outs section. Has anyone done > this? > > Another thought is a difference or differentiator module that could > generate triggers on discontinuities. Something like this could be > built from an analog shift register and a comparator, I suppose! > > Thanks, > Doug Not necessary :-) Module A-152 has a non-published feature (valid for all A-152 manufactured later than October 2004): RC4 of the PIC16F676 outputs a short 5V trigger signal whenever the address changes. RC4 is pin 6 of the PIC16F676 and is also available on pin 2 of the expansion connector JP6 (next to the bus connector on the A-152 main board / board A). Attention: the signal is not buffered/protected. You should at least add a protection resistor (~1k) if you want to connect it to a socket. Otherwise the PIC can be destroyed. Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] A-152 Modification: Trigger out on address selection
2008-12-18 by yahoo@doepfer.de
Attachments
- No local attachments were found for this message.