I found that the Epson nozzle check for the 1280 is not 100% reliable and sometimes I could get perfect nozzle checks but still banding when printing a purge pattern. In those cases, I went back to Epson or aftermarket DYE ink carts to clean up the nozzles perfectly. The dye ink seemed to restore the nozzles to no banding. Only then did I reinsert the UT2 carts and got perfect nozzles in both the traditional nozzle check and printing a purge pattern. If you're running a CFS, and the banding returns, it tells you the problem is foam in the carts not any problems with the nozzles. In that case see the MIS site for foam removal. Bob Michaels --- In DigitalBlackandWhiteThePrint@yahoogroups.com, "Pieris Berreitter" <pieris@y...> wrote: > > I've got a banding problem that showed up recently (after a nasty > clog, actually). Looking back at an old step wedge it's evident that > the problem is new. > > This forum doesn't work for showing pictures so I've got on one my > darkroom blog, where I compare banding in the 50% area of a step wedge > on three different paper types. > > I've gone through the head alignment effort as well as plenty of > windex cleaning cycles. Any hints, or should I just do some more? > > http://www.pmb.net/darkroom/2005/02/banding.html > > -Pieris > digital darkroom blog: www.pmb.net/darkroom
Message
Re: 1280/UT2 banding
2005-02-03 by Bob Michaels
Attachments