[Digital BW] Re: Uncoated papers -- MIS VM on Somerset Velvet

2001-09-20 by ken@kensmithart.com

Paul:
Your willingness to answer questions with this inkset, encourages me 
somehow to keep trying it with the uncoated papers that I like. That 
may seem strange, because your technical figures are not all that 
encouraging for somerset velvet. After all the work you've done to 
make the inkset available in the first place, I can sure keep 
experimenting with SV a bit longer!

I just printed some cards made of strathmore watercolor paper stock, 
using the VM inkset in my 1160, and they turned out really nice. So 
what the heck...

thanks,
ken


--- In DigitalBlackandWhiteThePrint@y..., "Paul Roark" 
<paul.roark@v...> wrote:
> Ken,
> 
> You wrote:
> 
> >I would be curious to know if you printed those step wedges on an
> >1160? ...
> 
> No, the results I noted were printed on a 3000.  My 1160 now has a 
different
> version of the variable-tone inkset in it.  I tried the SV with 
that, and
> found it to print cooler than I would have expected given the 
results with
> the 3000.  I don't know if it is due to the different pigment base 
or the
> printer.
> 
> >Was there considerable dot gain with your prints?
> 
> I'm not sure how to measure dot gain.  I do think, maybe I can see 
some
> bleeding along one edge, but I'm not sure -- it's not a big deal.  
On the
> other hand, a resolution chart printed on it is impressive.  The SV 
can
> resolve the 7.2 lp/mm target that represents the highest resolution 
of a 360
> dpi image file (alternating black and white, one-pixel-wide lines).
> 
> > Did you have other
> >curves in there to pare back the ink flow on the uncoated paper?
> 
> No.
> 
> > Did you try a test print of one of your images for comparison?
> 
> Yes.  In my view they look flat -- low contrast with weak blacks.
> 
> Paul
>