On Dec 14, 2005, at 3:36 PM, John Samperi wrote: > At 05:52 AM 15/12/2005, you wrote: >> 0/+3 happens to work on classic 1488/1489 buffers, "but its not >> right." >> >> Super serious workstations used to rigidly ahere to +-10 volts. > > > + - 25V being the 'right' voltage :-) The specified range is 3 to 30, positive and negative, with -3 to +3 being the "keep out zone". +-5 and +-12 used to be very common voltages to have inside a computer as Once Upon A Time common DRAM memory required negative voltage bias to operate. The 1488 driver dropped about 2 volts so when driven with +-12 its output would swing +-10. +-25 was much harder to drive a clean signal any interesting distance so the RS-232 spec is limited to 19,200 and 50'. Lower voltages work longer distances and higher data rates which prompted the move to LVD drivers. -- David Kelly N4HHE, dkelly@HiWAAY.net ======================================================================== Whom computers would destroy, they must first drive mad.
Message
Re: [AVR-Chat] Re: PC COM Ports
2005-12-15 by David Kelly
Attachments