--- In AN1x-list@yahoogroups.com, "tickles88keys" <tickles88keys@...> wrote: > > --- In AN1x-list@yahoogroups.com, "Jon" <jondl_2000@> wrote: > > Here's an example of how you might enter an NRPN string to control > Brightness (cutoff > > frequency): > > > > 98 74 Non-Reg LSB > > 99 00 Non-Reg MSB > > 6 0...127 Data MSB > > 38 0...127 Data LSB > > >> > Jon, > > Thanks for your reply. I'm not sure where you're getting 74 for the > LSB. Isn't it 20(Hex) or 32 according to the chart? 32 is for Bank Select. 74 is Brightness Either way, I'm > not able to get it to work with the BCR2000 for some reason. I think > that perhaps the MSB (01) isn't getting passed as such, and there's > no place to enter it as a stand-alone value. Is it possible that > somehow the MSB and LSB are combined to form a single value (much > greater than 127)? I've posted this question on the Behringer site, > but I haven't received a response from them... I downloaded a copy of their JAVA app, B-Control Editor, but I don't own either hardware device...try this: In the B-Control Editor, in the field for 'NRPN no.' select 98 then type 74 immediately following it so it reads 9874. I believe you will have to enter 127 for the 'Maximum' value in the left hand column for the full range of values of 0-127. Jon