Thanks Scott!
I had read that there were errors in the manual about CP test points but I wanted to be sure ..
So the voltage at FH and FL have been reversed? The manual says 4.0 Volt for HPF but the correct ones would be 3.3 Volt, and viceversa the manual says 3.3 Volt for LPF but the correct ones would be 4.0 Volt?
Now i understand why the calibration makes us crazy;)
And what is your experience about VCA 3 # (400 mV) and especially VCA 4 # (80mV) gains ?
Thanks again to share your experience and knowledge.
Best
Mark