Hi there.
You night have seen some discussions about this a few months ago. I had a hell of a time trying to calibrate a couple of CS80 envelopes. The same trimmers affect all times. I could not get any setting where both the attack and decay/release were both right.
Turned out that it was a bad timing capacitor! I replaced the 0.22uF cap on pin 2 of the IG000152/159 and then I could get it trimmed with no problems!
I'm not sure what kind of cap it is since I got the spare from another M card. Can someone fill us in on this?
David
Sent from my iPad
On Oct 25, 2011, at 1:40 PM, "Rainer" <rainer.keizer@...> wrote:
> I've looked through the adjustment procedures for the CS 60 and was wondering if it is possible to adjust the VCA or VCF release times for each voice? there is an adjustment for the attack, but I can't seem to find the release adjustment. I have a few voices that are quite a bit off, and as mine has just very recently had a major overhaul that cost 1.000 euros I'm a bit disappointed that the release needs re-calibration already.
> I do have to add that the temperature in my CS is quite a bit higher now it is always closed than it was when it was at the repair place, where it was mainly open.
>
> Any suggestions?
>
>
>
> ------------------------------------
>
> Yahoo! Groups Links
>
>
>