Archive of the former Yahoo!Groups mailing list: Discussion about the Korg PolySix synthesizer
Subject: Re: [PolySix] RE: Polysix tuning difficulties.
From: Malte Rogacki <gacki@gacki.sax.de>
Date: 2014-03-02
Measurements on and old production board. TP2 and TP3 are obscured by the
KLM396A board which must be removed.
TP2
16': -8.40
8': -11.02
4': -13.30
TP3
16': -9.93
8': -9.39
4': -2.40
TP3 with ground probe at TP4
16': +0.03
8': +0.97 (somewhat unstable occasionally more around +0.60)
4': +14.20
The last pair is a a bit of a mystery to me. Perhaps my multimeter is
freaking out.