Yup, it still sounds like the switch is in backwards. Not really a problem, as long as you know “normal” is the other direction.
Don B.
 
Sent: Tuesday, April 23, 2019 2:29 PM
Subject: [PolySix] Re: PolySix only works in test mode?
 
 

I have fixed the PCB bugs listed on the website, I even tried both capacitors on C23. No change in behavior.

Pictures of the PCB I have are here. I'm totally sure that I installed the switch correctly, it's on the component side with everything else. I didn't use the switch recommended on Jed's website, instead I got one of these switches, but from what I can tell they're electrically the same.


Another thing that I noticed is if I start the polysix in test mode, I can switch it back to normal mode once it's on and it still works normally. It's almost like the switch has no effect. However, if I start the polysix switched to normal mode, it does not work, and if I try to switch it to test mode while it's still on, it still doesn't work.