I was trying to get my KLM366 board tuned up - and in the middle of everything I managed to blow up my power supply (KLM 376 IIRC) . A clean blowout of the 2200µF filter cap. Took both fuses with it. So I ordered all new caps from Mouser and rebuilt it without incident. But NOW it looks like both PGM 3 and VERIFY lights are perpetually on. Apparently the blowout of the cap may have affected something downstream (on the KLM 367 board) ??
I promised Andy Jury who fixed up my replacement board for me that I wouldn't touch any adjustments on his board - so i thought I'd ask here before consulting him - just in case it may possibly be something else - or looks familiar to someone as a problem they've had (?)
thanks mucho