Archive of the former Yahoo!Groups mailing list: Discussion about the Korg PolySix synthesizer

previous by date index next by date
previous in topic topic list next in topic

Subject: Re: [PolySix] Re: Polysix 100/120V to 220/240V conversion - Swapping transformer?

From: Johannes Hausensteiner <johannes@eclipso.at>
Date: 2014-12-29

> Measured the AC-voltage coming out from the step-down converter, and
> it's 127V! (126.8V) That's no good.
This is indeed quite high (+27%)

> Could someone please list the effects on a Polysix (or any synth
> /audio equipment for that matter) rated for 100V when the incoming
> voltage is +27V?
Since it is a simple AC transformer it will transfer the primary voltage
faithfully to the secondary side. This means that the power supply
(KLM-376 in case of the Polysix) will get a voltage 27% above nominal.

> I've read that a transformer receiving excessive voltage will
> overheat, but will components literally die from this? What
> components are affected by long term use of +27V of excessive voltage?
The overvoltage will cause excessive heat mainly on the power
transistors and possibly on the transformer itself. This might lead to
a premature aging and failing of the power supply.

> Also measured the AC-output from the wall socket today. Its 235V.
This is perfectly OK and normal. The nominal voltage is 230V +10/-15%

> Should i get a 225VA or a 250VA transformer for the Polysix? Can't
> see that the local store sells any 240VA transformers.. only 225VA
> and 250VA in that VA-range.
This is a misunderstanding. The physical unit "VA" means "Volt Ampere",
Which is effectively Volts ∗ Amperes, which denotes a power rating.
The type label of my Polysix reads 25W (which is in that case the same
as VA; although there is a subtle difference between "VA" and "W"...).
So the proposed 80VA transformer
(http://www.altronics.com.au/p/m5118-powertran-18-18-80va-toroidal-transformer/)
is way over-dimensioned. Even if you have additional circuitry like a
MIDI upgrade inside your Polysix you should be on the safe side with a
35 - 40VA type. The secondary AC voltage on my polysix reads ca. 19.4V
each output (the secondary has a center tap to generate +/-15V).
So 2x 18..20V transformer with ca 35..40VA is fine.
The proposed toroid type is superior in terms of stray inductance to
standard M- or EI- types. This might result in less (magnetic) induced
hum; but I would not expect too much of that.

BUT: According to the KLM-376 schematics the transformer has a second
tap on the primary to adapt for 100V (Japan) and 110/115V (e.g. U.S.).
This is very common to such transformers. So possibly all you have to do
is rewiring the AC mains wires and use the 120V setting. It says on the
schematics th orange wire should be used and the brown wire should be
left unconnected (actually there is a solder tap labeled "nc", which
stands for "not connected" on the KLM-425 filter PCB. But this can be
different in your unit.

I hope this helps!

Johannes



Am 29.12.2014 um 05:21 schrieb stalinjohansen@yahoo.com [PolySix]:
>
>
> Measured the AC-voltage coming out from the step-down converter, and
> it's 127V! (126.8V) That's no good.
>
> Could someone please list the effects on a Polysix (or any synth/audio
> equipment for that matter) rated for 100V when the incoming voltage is +27V?
>
> I've read that a transformer receiving excessive voltage will overheat,
> but will components literally die from this? What components are
> affected by long term use of +27V of excessive voltage?
>
>
>
>