Subject: I killed my PolySix

From: <jeremy.pisani@gmail.com>
Date: 2014-04-29

So, I did a stupid thing. I got my PolySix a few years back, and it had the leaky battery issue. I sent the board off to be fixed by Old Crow's synth shop, and after that it was working great, except for the buttons being finicky, and the Hold button didn't work at all. After a lot of procrastinating, I finally ordered some new switches and went to work desoldering & replacing the buttons. 


At first I checked to make sure the synth was still functioning correctly after I replaced each button, but after 5 or so I felt confident enough to keep going without checking (I'm kicking myself as I write this). When all was said & done I powered it up and it's behaving like it did when I first got it. When powered on, the Write & Manual buttons light up, as well as the Bank C, Poly, and Program 3 & 5-8 buttons. I can switch between Poly/Unison/Chord Memory & Hold buttons with no problem, but it doesn't affect the sound. None of the knobs seem to affect anything either.


 I did a lot of the desoldering without putting something over the circuit boards to protect them from solder flecks, and I'm guessing maybe something got fried when I powered it on, but honestly, I don't know. I did a little poking around with a multimeter & got the following results:


Power supply voltage: 

4.2/-4.2

14.6/-14.6


All ICs on the KLM-376A are reading 4.8v except for the following:


IC14: 3.5v

IC20: 3.6v

IC21: 4.1v

IC25, IC32: 4.1v

IC34: 4.6v


Continuity between the previously repaired traces seems to be fine. Any ideas?